Vacuum Pumps and Vacuum Generators
Small Compressed Air Venturi Vacuum Pumps

VR Series – Advanced, Aluminum Bodied Mini Vacuum Pumps

With the ANVER VR Series Mini Vacuum Pumps, you can connect compressed air directly to your vacuum cup. This connection creates a vacuum at the load, which minimizes the potential for loss of vacuum through tubing.

These mini vacuum generators can be used to transform a vacuum cup into a complete lifting system. Several mini-generators can be mounted to a compressed air manifold system to pick up large groupings of separate items or one load. If some items are missing, the other items will not lose vacuum because they each have a separate air supply. Simply shut off the exhaust port or the supply of compressed air to release the load.

ANVER recommends using the VR05 for cups with a diameter of up to 1″ (25 mm), and the VR07 or VR09 for cups between 1″ (25 mm) and 4″ (102 mm). Any model may be used on all small cups, and all systems should be tested for suitability.

Features

  • Compact – only the size of a fitting
  • Economical – no moving parts to break down
  • Simple mounting and construction
  • Low air consumption
  • Lightweight yet rugged
  • Mounts directly to the suction cup for millisecond attach/release packaging applications (optional)
Technical DrawingUsed with These CupsUsed with These Suspensions


Small Suction Cups

SLSA1 Suspensions
(M5 NPT)
SLSA 2
 SLSA2 Suspensions
(G 1/8″ male)

 

Specifications

RFQ3D Content CentralTracePartsProduct Photo
(Click to Enlarge)

Part Number

Top
Supply Port
Bottom
Vacuum Port
Side
Exhaust Port

Vacuum Flow
SCFM
(l/min.)

Max. Vacuum Level
in. Hg
(mm Hg)

Air Consumption
SCFM
(l/min.)

Supply Pressure
(psi)

 

3D3Dvr05VR051/4″ NPT
Female
Thread
6 mm
Female
Thread
M5
Male
Thread

0.50
(14)

26
(660)

0.74
(21)

72.5

 

3D3Dvr05-gVR05-GG 1/4″
Female
Thread
6 mm
Female
Thread
M5
Male
Thread
0.50
(14)
26
(660)
0.74
(21)
72.5

 

3D3Dvr07VR071/4″ NPT
Female
Thread
1/8″ NPT
Female
Thread
M5
Male
Thread

0.50
(14)

26
(660)

0.74
(21)

72.5

 

3D3Dvr07-gVR07-GG 1/4″
Female
Thread
G 1/8″
Female
Thread
M5
Male
Thread
0.50
(14)
26
(660)
0.74
(21)
72.5

 

3D3Dvr09VR091/4″ NPT
Female
Thread
1/8″ NPT
Female
Thread
M5
Male
Thread

0.74
(21)

26
(660)

1.27
(36)

72.5

 

3Dvr09VR09-GG 1/4″
Female
Thread
G 1/8″
Female
Thread
M5
Male
Thread
0.74
(21)
26
(660)
1.27
(36)
72.5

 

Air Consumption and Vacuum Flow at Different Vacuum Levels (-Hg) at 72.5 psi

Model
Number
Air
Consumption
SCFM
(l/min.)
Vacuum Flow at Vacuum Level
SCFM
(l/min.)
0 Hg3 Hg6 Hg9 Hg12 Hg15 Hg18 Hg21 Hg24 Hg26 Hg
VR050.50
(14)
0.50
(14)
0.45
(12.7)
0.40
(11.33)
0.34
(9.63)
0.25
(7.08)
0.21
(5.95)
0.17
(4.81)
0.11
(3.11)
0.05
(1.42)
0.00
(0.00)
VR070.50
(14)
0.50
(14)
0.45
(12.7)
0.40
(11.33)
0.34
(9.63)
0.25
(7.08)
0.21
(5.95)
0.17
(4.81)
0.11
(3.11)
0.05
(1.42)
0.00
(0.00)
VR090.74
(20.9)
0.74
(20.9)
0.65
(18.41)
0.57
(16.14)
0.47
(13.31)
0.40
(11.33)
0.33
(9.34)
0.25
(7.08)
0.15
(4.25)
0.08
(2.27)
0.00
(0.00)

 

Vacuum Time to Evacuate at 1cu/ft.

Model
Number
Vacuum Time
Seconds to 1cu/ft.
0″3″6″9″12″15″18″21″24″26″
VR0501531.751.374.2102.5138.8190277.5568
VR0701531.751.374.2102.5138.8190277.5568
VR0908.518.129.242.558.679.3108.5158.6324.8

Important: Use caution when VR vacuum pump is connected directly on a cup. There is no check valve in the system to prevent the load from releasing if compressed air power is lost.

Examples of Components


Tech Specs

Technical and Performance Specifications for Various Nozzle Sizes