Vacuum Pumps and Vacuum Generators
Small Compressed Air Venturi Vacuum Pumps
VR Series – Advanced, Aluminum Bodied Mini Vacuum Pumps
With the ANVER VR Series Mini Vacuum Pumps, you can connect compressed air directly to your vacuum cup. This connection creates a vacuum at the load, which minimizes the potential for loss of vacuum through tubing. These mini vacuum generators can be used to transform a vacuum cup into a complete lifting system. Several mini-generators can be mounted to a compressed air manifold system to pick up large groupings of separate items or one load. If some items are missing, the other items will not lose vacuum because they each have a separate air supply. Simply shut off the exhaust port or the supply of compressed air to release the load. ANVER recommends using the VR05 for cups with a diameter of up to 1″ (25 mm), and the VR07 or VR09 for cups between 1″ (25 mm) and 4″ (102 mm). Any model may be used on all small cups, and all systems should be tested for suitability. |
||
Features
|
Technical Drawing | Used with These Cups | Used with These Suspensions | |
|
Small Suction Cups |
SLSA1 Suspensions (M5 NPT) |
SLSA2 Suspensions (G 1/8″ male) |
Specifications
Air Consumption and Vacuum Flow at Different Vacuum Levels (-Hg) at 72.5 psi
Model Number |
Air Consumption SCFM (l/min.) |
Vacuum Flow at Vacuum Level SCFM (l/min.) |
|||||||||
0 Hg | 3 Hg | 6 Hg | 9 Hg | 12 Hg | 15 Hg | 18 Hg | 21 Hg | 24 Hg | 26 Hg | ||
VR05 | 0.42 (12) |
0.25 (7.08) |
0.22 (6.23) |
0.19 (5.38) |
0.16 (4.53) |
0.13 (3.68) |
0.10 (2.83) |
0.07 (1.98) |
0.04 (1.13) |
0.01 (0.283) |
0.00 (0.00) |
VR07 | 0.74 (21) |
0.50 (14) |
0.45 (12.7) |
0.40 (11.33) |
0.34 (9.63) |
0.25 (7.08) |
0.21 (5.95) |
0.17 (4.81) |
0.11 (3.11) |
0.05 (1.42) |
0.00 (0.00) |
VR09 | 1.27 (36) |
0.74 (20.9) |
0.65 (18.41) |
0.57 (16.14) |
0.47 (13.31) |
0.40 (11.33) |
0.33 (9.34) |
0.25 (7.08) |
0.15 (4.25) |
0.08 (2.27) |
0.00 (0.00) |
Vacuum Time to Evacuate 1 cubic foot (28.3 liters)
Model Number |
Vacuum Time Seconds to 1cu/ft. |
|||||||||
0″ | 3″ | 6″ | 9″ | 12″ | 15″ | 18″ | 21″ | 24″ | 26″ | |
VR05 | 0 | 25.5 | 54.4 | 87.8 | 127.4 | 175.6 | 237.9 | 325.6 | 475.7 | 974.4 |
VR07 | 0 | 15.0 | 31.7 | 51.3 | 74.2 | 102.5 | 138.8 | 190.0 | 277.5 | 568.0 |
VR09 | 0 | 8.5 | 18.1 | 29.2 | 42.5 | 58.6 | 79.3 | 108.5 | 158.6 | 324.8 |
Important: Use caution when VR vacuum pump is connected directly on a cup. There is no check valve in the system to prevent the load from releasing if compressed air power is lost.
Examples of Components |
|
Technical and Performance Specifications for Various Nozzle Sizes