Vacuum System Components
JTSED Electronic Vacuum Switch with Digital Readout

JTSED Electronic Vacuum Switch with Digital Readout

The JTSED Electronic Vacuum Switch converts the vacuum level into digital output for connection to PLC systems as well as into analog output for the on/off control. The JTSED Electronic Vacuum Switch is identical to the JTSE Switch except for the addition of a digital LED display. Vacuum levels can be manually adjusted in psi, bar, or in Hg over the full range of vacuum.

 

 

Specifications for JTSED Vacuum Switch

Part Number Recommended
Polyurethane Tubing*
Schematic
JTSED

 

* Note: 5/32″ O.D. (3/32″ I.D.) tubing connects to 3/32″ barb

The JTSED Digital Vacuum Switch mounts easily and conveniently under the nozzle and muffler of the ANVER JB Series Vacuum Generators. The switch is provided with 6.5 ft (2m) of connection cable.

 

Specifications for JTSED Vacuum Switch

Rated Pressure Range 0.0 ~ -101.3kPa
Operating/Setting Pressure Range 10.0 ~ -101.3kPa
Withstand Pressure 3 Times of Rated Pressure Range
Fluid Air, Non-Corrosive Gases, Incombustible Gases

Set Pressure
Resolution

kPa 0.1
MPa
kgf/cm² 0.001
bar 0.001
psi 0.01
In. Hg 0.1
mm Hg 1
mm H20 0.1
Power Supply Voltage 12 to 24 VDC ±10% Ripple (P – P) 10% or less
Current Consumption ≤ 55mA
Switch Output PNP open collector 2 outputs
Max. load current: 80mA
Max. supply voltage: 30VDC
Residual voltage: ≤ 1V (load current 80mA)
Repeatability (Switch Output) ≤ ±0.2% F.S. ±1 1igit
Hysterisis Hysterisis Mode Adjustable
Window Comparator Mode Fixed (3 digits)
Response Time ≤ 2.5 ms (chattering-proof function: 24 ms, 192 ms and 768 ms selections)
Output Short Circuit Protection Yes
7 Segment LED Display 3½ digit LED 7 segment display (Sampling rate: 5 times/1 sec.)
Indicator Accuracy ≤ 2% F.S. ± 1 digit (ambient temp.: 25 ±3° C)
Indicator Green LED (Out 1) Red LED (Out 2)

Environment

Enclosure IP40
Ambient Temp. Range Operation: 0~50° C, Storage: 20~60% RH (No condensation or freezing)
Ambient Humidity Range Operation/Storage: 35~85% RH (No condensation)
Withstand Voltage 1000VAC in 1-min (between case and lead wire)
Insulation Resistance 50Mohm min. (at 500VDC M, between case and lead wire)
Vibration Total amplitude 1.5mm, 10Hz-55Hz-10Hz scan for 1 minute, two hours each direction of X, Y and Z
Shock 980m/s² (100G), 3 times each in direction of X, Y and Z
Temperature characteristic ≤ ±2% F.S. of detected pressure (25° C) at temp. Range of 0~50° C
Port Size F1:1/8″NPT, M5; F2: 1/8″NPT, M5; F3: G1/8″, M5
Lead Wire Oil-resistance cable (0.15mm²)
Weight Approx. 67g (with 2-meter wire) Approx. 35 g (with male connector)