Vacuum Pumps and Vacuum Generators
Multi-Stage Air Powered Vacuum Pumps with External Exhaust Silencer MSP Series
Model No. MSP800

ANVER MSP800

Dimensional Specifications for MSP800

Schematic of Multi-stage Ejector Vacuum Pump
Request
for Quote

Model
Number

MSP800

 

Model
Number

Equivalent P-Series
Pump Number

Max Vacuum
in. Hg
(mm Hg)

Vacuum Flow
SCFM
(l/min.)

Air Consumption
SCFM
(l/min.)

MSP800

ML800

27
(690)

338.88
(9600)

101.66
(2880)

Air consumption and vacuum flow at different vacuum levels (-Hg) at 87 psi.

Model
Number
Air
Consumption
SCFM
(l/min.)
Vacuum Flow at Vacuum Level
SCFM
(l/min.)
0 Hg 3 Hg 6 Hg 9 Hg 12 Hg 15 Hg 18 Hg 21 Hg 24 Hg
MSP800 101.66
(2880)
338.88
(9596)
236.51
(6700)
157.09
(4448)
79.07
(2239)
56.13
(1590)
44.48
(1260)
33.54
(950)
22.24
(630)
13.41
(380)

The “G” thread is a straight pipe thread also known as BSPP, NPS, or G, commonly used in Europe, Asia, and most of the world.