Vacuum Pumps and Vacuum Generators
Multi-Stage Air Powered Vacuum Pumps with External Exhaust Silencer MSP Series
Model No. MSP150

ANVER MSP150

Dimensional Specifications for MSP150

Schematic of Multi-stage Ejector Vacuum Pump
Request
for Quote

Model
Number

I
in.
(mm)

MSP150

3.39
(86)

 

Model
Number

Equivalent P-Series
Pump Number

Max Vacuum
in. Hg
(mm Hg)

Vacuum Flow
SCFM
(l/min.)

Air Consumption
SCFM
(l/min.)

MSP150

 

27
(690)

74.13
(2100)

24.71
(700)

Air consumption and vacuum flow at different vacuum levels (-Hg) at 87 psi.

Model
Number
Air
Consumption
SCFM
(l/min.)
Vacuum Flow at Vacuum Level
SCFM
(l/min.)
0 Hg 3 Hg 6 Hg 9 Hg 12 Hg 15 Hg 18 Hg 21 Hg 24 Hg
MSP150 24.71
(700)
74.13
(2100)
52.95
(1500)
34.60
(980)
18.36
(520)
12.71
(360)
10.59
(300)
7.59
(215)
4.94
(140)
2.97
(84)

The “G” thread is a straight pipe thread also known as BSPP, NPS, or G, commonly used in Europe, Asia, and most of the world.