Vacuum Pumps and Vacuum Generators
ANVER Q-VDF Series Adjustable Vacuum Pumps
Q-VDF500

 

Performance and Dimensional Specifications:

Model
Number
Air Consumption vs. Vacuum Level (“Hg) @ 80 PSI
0″ 5″ 10″ 15″ 20″ 25″
Q-VDF500 0 12.00 22.00 28.00 33.00 45.00

Model
Number
Vacuum Flow (SCFM) vs Vacuum Level (“Hg) @ 80 PSI
0″ 5″ 10″ 15″ 20″ 25″
Q-VDF500 0 23.00 35.00 40.00 47.00 60.00

Model
Number
A
Barrel ID
in.
(mm)
B
in.
(mm)
C
Collar Length
in.
(mm)
D
in.
(mm)
E
Input
F
Barrel OD
in.
(mm)
G
Collar OD
in.
(mm)
H
in.
(mm)
I
Thread
J
Thread
Q-VDF500 0.500
(12.7)
1-1/2
(38.1)
2
(50.8)
1
(25.4)
G3/8″ 1-1/4
(31.8)
2
(50.8)
2-1/2
(63.5)
G3/4″ G1/2″