Vacuum Generators and Vacuum Stations
Self-Contained Battery Powered Vacuum Stations
BAE3-GEN3 Series with ANVER Vacuum Control Module & Safety Lock-Out

ANVER’s BAE3-GEN3 Series Vac-Pack Vacuum Generator contains many of the same features as the standard VPE3-GEN3 Series. Designed for use with a wide assortment of vacuum pad attachments and lifter assemblies, these high quality Vac-Packs are ruggedly designed for heavy production use. Units are available with heavy duty frames or for mounting remotely. The BAE3-GEN3 Series includes a rechargeable, heavy duty 12 volt DC 105 Amp hour battery, making it suitable for handling non-porous loads. It is commonly used for special applications where AC power is not readily available.

Safety Features:

  • Load Sensing Lifting Bail with Safety Lock-Out
    Pendant controls are only active when the lifter is lowered completely and there is no load on the bail.  This eliminates the risk of accidental release of a suspended load by the operator. (Feature not present on the BAE3-GEN3-RD Series, which is a standalone version, or the BAE3-GEN3-T, which is a tilter version.)
  • Vacuum Control
    A solid-state Vacuum Control combines all the required vacuum generator controls in one rugged unit. This controls all vacuum pump functions, safety lights and is fitted with a standard audible vacuum leakage warning system.
  • Energy Saver Technology
    A vacuum-controlled valve shuts off the vacuum pump when the pre-set vacuum level is reached, reducing wear and tear on the pump.

 

Anver_Air_Saver_Tag

 

  • Audible Vacuum Leakage Warning System
    Integrated electronically controlled vacuum leakage sensor monitors vacuum level and will sound an alarm if a slow vacuum leak is present when the vacuum level drops to a pre-determined set point.
  • Vacuum Retention
    The system includes an internal check valve to stop leakage of vacuum in the event of a power failure (non-porous loads).  A 5.4 gallon (1247 cu. in.) vacuum reservoir assists in maintaining a safe vacuum level during a power failure (non-porous loads).

Additional Features:

  • Front Control Panel and Gauges
    All gauges, lights, and power switches are mounted on the front of the control panel. The two vacuum gauges on the face of the panel display the level of vacuum in the manifold and in the reservoir.
  • Indicator Lights – Front, Left & Right Side
    Green light indicates “Safe” vacuum level.
    Red light indicates “Unsafe” vacuum level.
    White light indicates “Power On.”
  • Battery Charger (CHARGER-BAE) (Sold Separately)
    The battery charger is designed specifically for today’s high performance, deep-cycle lead-acid batteries. The straight blade plug accommodates a standard extension cord using a 110V AC wall outlet.

Generator shown with ESC Controls

Your choice of FOUR control styles to suit your application:

Standard Controls

Click for Video

Electric Self-Cycling Attach/Release
Instant attach/release is provided via the hoist up and down movement. The attach and release alternate each lift cycle for fast, efficient handling. Similar to our line of Mechanical Generators. Click here to find out more about Electric Self-Cycling.

Features:

  • No Pendant or Radio Controls Required for Attach/Release.
  • Extremely Safe. Load cannot be released until it is set down on a surface.
  • Simple to operate.
Optional Controls

Radio Controlled 3 Button Attach / Release / Interlock Transmitter with Plug-In Receiver
Hand held device with attach, release and safety interlock push buttons with holster mounted on front handlebar. Plug-in receiver is mounted on side of vacuum generator.  Contact Factory for more information.

Includes:

  • Radio Control Transmitter and Mounting Holster
  • Radio Control Receiver and Mounting Bracket

Plug-In Attach / Release / Interlock Control Pendant
Attach/Release momentary switch and safety interlock push-button located on control pendant with 10ft long coiled cord.

Includes:

  • Pendant Control and Mounting Holster
  • Plug-In, Replaceable Coil Cord, 10 ft. long.

Plug-In Harness, Customer Radio Receiver Interface
 Control Harness allows you to wire your own radio receiver for integration of Attach / Release / Interlock.

Includes:

  • Cord, 3 ft. long.

 

  • Ergonomic Control Handlebar
    Easy to grasp, large loop handlebar enables the operator to easily and safely maneuver the attached load without touching the load itself. Handlebar can be adjusted for smaller size loads.
  • Twist-Lock Power Cord Connector
    The twist-lock receptacle prevents accidental disconnection from the power source.  Both male and female halves are supplied.

Maintenance:

  • Front & Rear Panel Cover
    The front and rear covers pivot open for easy access to all components.
  • Air Filter
    Over-sized air filter provided inside of front cover features a screw-on clear filter bowl for easy filter inspection and cleaning.
  • Removable Battery Case Cover
    Standard battery case with strap and cover provides easy access to the battery, which is mounted on a rugged mounting bracket(s) bolted directly to the Vac-Pack.
  • Battery Cable Plugs
    Allows easy connection and disconnection to and from the Vac-Pack during battery maintenance or replacement.

Vacuum Pump(s):

  • The (3) diaphragm type vacuum pumps at 7.5 CFM total are driven by 1/16 h.p. 12 volt D.C. motor and generate 24” Hg. (at sea level) of vacuum. The ANVER Vacuum Control Module maintains a safe vacuum level by cycling the vacuum pump motor on or off as required, which extends both vacuum pump life and battery charge.

Battery Specification:

  • 79 Amp hour, deep-cycle battery can provide up to 8 hours of continual operation in many applications.

Options:

  • Optional Moisture Traps (WT-VP3-[Series])
    For damp applications: prevents saturation of filter and possible damage to pump. Not for handling wet loads. Mounts on vacuum manifold.
  • *Optional Generator Configurations and Voltages Available:
    In reference to our standard line of Vac-Packs noted above, other configurations, voltages and set-ups are available. Contact ANVER for further information and application requirements.

 

Specifications for Lifting Frames and Pad Attachments:

 
Request For Quote
Generator Series Model No.BAE3-GEN3-LBAE3-GEN3-SBAE3-GEN3-HBAE3-GEN3-HDBAE3-GEN3-X
Rated Load Capacity [lbs (kg)]2300 (1043)6900 (3129)7000 (3175)10000 (4535)10000 (4535)
Unit Weight [lbs (kg)]474 (215)474 (215)474 (215)474 (215)474 (215)
A Max. Headroom [in. (mm)]30.13 (765)31.5 (800)31.5 (800)31.5 (800)28 (711)
B Handlebar Height [in. (mm)]12.44 (316)13.81 (351)13.81 (351)13.81 (351)12.31 (313)
C Unit Width [in. (mm)]25.38 (645)26.13 (664)26.13 (664)26.13 (664)26.13 (664)
D Maximum Handlebar Length [in. (mm)]34 (864)34 (864)34 (864)34 (864)34 (864)
E Hardware Centers [in. (mm)]9 (229)22.38 (568)22.38 (568)23.38 (594)23.38 (594)
F Fits Tube Size [in. (mm)]3 x 3 (76 x 76)3 x 6 (76 x 152)5 x 7 (127 x 178)5 x 7 (127 x 178)8 x 6 (203 x 152)
G Vac-Pack Depth [in. (mm)]18.84 (479)18.84 (479)18.84 (479)18.84 (479)18.84 (479)
H Hardware Spacing [in. (mm)]N/AN/AN/AN/A4 (102)
(3) Total Pump Capacity SCFM7.57.57.57.57.5
Vacuum Level at Sea Level [in. Hg ]2424242424
Energy Saver / Quiet Automatic Shut-OffYESYESYESYESYES
Battery Part NumberAGM-12V-75AGM-12V-75AGM-12V-75AGM-12V-75AGM-12V-75

 

Specifications for Remote Mounting:

Request For Quote
Generator Series Model No.BAE3-GEN3-R
Unit Weight [lbs (kg)]270 (123)
A Max. Headroom [in. (mm)]23.63 (600)
B Unit Width [in. (mm)]29.31 (744)
C Unit Depth [in. (mm)]25.38 (645)
Vacuum Level at Sea Level [in. Hg]24
Energy Saver / Quiet Automatic Shut-OffYES
Battery Part NumberAGM-12V-75
Operator Control Style OptionsRadio Control or Pendant Control
(Electric Self-Cycling not compatible with this model)

Specifications for Tilters:

Request For Quote
Generator Series Model No.BAE3-GEN3-T
Unit Weight [lbs (kg)]270 (123)
A Max. Headroom [in. (mm)]22.44 (569)
B Unit Width [in. (mm)]18.88 (479)
C Unit Depth [in. (mm)]25.38 (645)
Hardware Mounting PatternD x FG Thread: (4) M20x2.512 x 8 (305 x 203)
E x FH Thread: (4) M10x1.514 x 8 (356 x 203)
Vacuum Level at Sea Level [in. Hg]24
Energy Saver / Quiet Automatic Shut-OffYES
Battery Part NumberAGM-12V-75
Operator Control Style OptionsRadio Control or Pendant Control
(Electric Self-Cycling not compatible with this model)

 

Optional Controls
Product
Photo
Part
Number
Description
RCPK-AC/DC-ARI

Radio Control Kit for Vac-Packs, Attach/Release/Interlock

Kit Includes:

  • Radio Control Transmitter and Mounting Holster
  • Radio Control Receiver and Mounting Bracket
EPK-AC/DC-ARI

Pendant Control Kit for Vac-Packs, Attach/Release/Interlock

Kit Includes:

  • Pendant Control and Mounting Holster
  • Plug-In, Replaceable Coil Cord, 10 ft. long.
34000332

Plug-In Harness, Customer Radio Receiver Interface

Kit Includes:

  • Cord, 3 ft. long.
Battery Charger and Accessories
Product
Photo
Part
Number
Description
CHARGER-BAE

  Battery Charger, Smart Charge (12 VDC) w/ Adapter Harness

  Includes:

  • Battery Charger/Maintainer
  • Harness, Battery Charger, Modified Connector

 

Recommended Spare Parts
Product
Photo
Part
Number
   Description
34000152    Pendant Coil Cable Replacement / Extension, 10 Ft. Long, Plug-In
21301185-2    Utility Bar Assembly for 1.25″ Dia. Handlebars (VPE3-GEN3 / BAE3-GEN3 / GF Series)
21301186    Radio Control Transmitter Holster Assembly, Bolt-on for Utility Bar (Mounting Hardware Included)
21301187    Pendant Mounting Bracket Assembly, Bolt-on for Utility Bar (Mounting Hardware Included)
RCT-PCLIP    Plastic Belt Clip for RCT Transmitter
RCT-MCLIP    Metal Belt Clip for RCT Transmitter
RCT-SCREW    Belt Clip Screw for RCT Transmitter
RCT-NYLONCOVER    Protective Nylon Cover for RCT Transmitter
back-generators lifters-back